smallest ethernet-gateway with PD-socket, multifunctional, 1 adapter for all PPI, MPI and Profibus applications
with ext. 24V-connector

  • Supplied driver TIC (Total Integrated Communication) (runs under Win XP, VISTA, Win7/8/8.1, Win10) allows communication and configuration of the interface product
  • Function with TIA-Portal and Simatic-Manager, also with WinCC and Comfort Panel
  • Automatic protocol- and baud rate detection (depends on the used product from 9K6 to 12M)
  • Connects only to the bus when it is requested by PG
  • Firmwareupdate via internet for free
  • PPI - adapter for S7 - 200
  • MPI/Profibus - adapter for S7 - 300 + 400
  • CE/EMC compliant construction
  • All intelligent MPI-interface-products including a free OPC-server license "OPC-Manager lite" [limited to 100 items]
  • All products, including the examples and demo-version of communication driver as download on the product-site
  • Master-class 2 for acyclic services (DPV1)
  • PUT/GET from S7-1500/1200/300/400(PN or with ethernet-cp) with spezific and unspezific connection possible
  • Cyclic read of time from NTP server and set in the connected PLC
  • Coupling with DB-transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or S5 Gateway
  • Power supply from the S7-PLC or external
  • Network configuration free adjustable
  • VPN remote maintenance possible / for the maintenance of the PLC via Internet
  • With full PD – diagnosis socket
  • Active module, no influence on further bus-clients in the system
  • Coupling of two PLC's S7 - S7 / S7 -S5 is possible with the Gateway type
  • Provides the coupling with Android operating-system [for example S7Droid]

Technical data


Supply voltage: 24V/DC +/- 20%
Power consumption: 2 watt
Display: Web-Browser
2 status-LEDs
Handling/Configuration: Web-Browser
Kabelmanager-Software
Interfaces:
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
to the PD/PC:
PD/diagnosis jack
10/100BaseTX RJ45-ethernet jack
Galvanic separation: 1500V PPI/MPI/Profibus to the PC
Protocols: RFC1006, DHCP, HTTP
Operating temperature: 5 - 55°C
Case: ABS-plastic case
Dimensions: 65 x 43 x 17 mm
Scope of delivery:
S7-LAN-module
Power connector 2pins small
Commercial data:
EAN number: 4260363240017
HS-code: 85423190
Weight: 0.0600 kg

technical data
docu / downloads

Applications

Programming of S7-PLC-devices via LAN

You would like to respond to your S7-PLC-device via LAN but not integrate an Ethernet-CP? No problem, plug the S7-LAN or also the MPI-LAN-cable on the MPI/PPI/Profibus-interface and access via LAN.
Watching of S7-PLC-devices via LAN without Ethernet-CP

Your panel only has a LAN-socket as PLC-interface? No problem, connect this socket with the S7-LAN or the MPI-LAN-cable and plug it directly on the PPI/MPI/Profibus of the PLC. Then access to the variables and data of the PLC is already available.
S7-CP-replacement (without LAN-CP to the PLC-device)

Do you have a S7-PLC-device without CP243-1, CP343-1 or CP443-1 and would like to connect via LAN? Then plug the S7-LAN on the PLC-device and your access via RFC1006 is ready for use.
Remote maintenance of your S7-PLC-device via LAN / Internet

You have access to a on-site network and your PLC-device has no LAN-connection? No problem, plug the S7-LAN on the PLC-device and you will have immediate access to the PLC from afar.
Without LAN-cable round of the PLC

Your’re right in the middle of your production line and and should move around the machine and simultaneously observe / manage. No problem, you parameterize the ALF, connect to the S7-LAN and connect to the WIFI-network of the ALF and are ONLINE on the PLC.

Transformation of Rack/Slot in TSAP to MPI-address

Your panel or visualisationsystem addresses the used PLC with Rack/Slot in TSAP? No problem, activate this mode in the S7-LAN and you will get actual data from the PLC.
PLC coupling (data exchange between PLC-devices)

Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Thereto no dedicated line is required, it’s sufficient when the stations connect via network (DSL-router).
Actual time for the PLC?

You need in your PLC a actual time? No problem, with the NTP-function the S7-LAN-module get from a NTP-(Time-)Server the actual time and transfers it direct into the configured PLC or for processing in a DB.
Variable-chart without Step7-programming package

You would like to give your customer the opportunity to read current numbers of the manufacturing Online, without installing a visualisation or even the STEP7-package? Then a S7-LAN with the option „Status Variable“ is needed, and your customer can take a look at these password protected data on a site of the integrated webserver.
Malfunctions on the Bus although everything is (apparently) connected properly?

The S7-LAN can also be used for controlling/checking the MPI/Profibus. It will be plugged on the Bus so that you can take a look at the status of the busses via software on PC, for example the numbers of parity errors.
applications technical data

technical data
applications
docu / downloads

article:
Art. ID.name
9352-LANCONS7-LAN connector for Siemens S7 Controller
Ethernetmodule for PPI/MPI/Profibus

applications technical data
options:
Art. ID.name
9352-IPDEVICETOS7IPDeviceToS7
IP-devices writing/reading DB in S7-PLC
9352-PUTGETOption PUT/GET
Active PUT/GET-connection to an other network-
client
9352-VASTOption
view of variables in web browser with
setpoint monitoring and e-mail-alerts
9352-WATCHDOGOption Watchdog
controlling of the connected MPI-/Profibus
with webbrowser or over port

applications technical data
accessories:
Art. ID.name
9352-24Power connector 2pins small
cable coupling by screw-connector (small)
9352-RS485-SKStub-compensator without galv. separation
9391-USBUSB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids
24V DC, maximum current: 125mA (for PC
100mA)
length: 5m
9391.124V DC power-supply unit 625mA
Primary 110V - 240 VAC Euro+USA-plug
9636-CROSSCross-cable 3m Cat5+, shielded
RJ45 plug <=> RJ45 plug, twisted pinning
9636-TCPIPPatch-cable 3m, Cat5+, shielded
RJ45 plug <=> RJ45 plug, 1:1