Cookies helfen uns bei der Bereitstellung unserer Dienste. Durch die Nutzung unserer Dienste erklären Sie sich damit einverstanden, dass wir Cookies setzen.
Cookies help us in providing our services. By using our services, you agree that we set cookies.
OK








Technologie Partner Automation e.V.

Deutsch

English

Website-search





(c) copyright
2000 - 2018
by TPA





TPA

MPI-LAN

S7-Interface cable for PPI, MPI, Profibus, HMI <=> LAN applications

  • Supplied driver TIC (Total Integrated Communication) (runs under Win XP, VISTA, Win7/8/8.1, Win10) allows communication and configuration of the interface product
  • Function with TIA-Portal and Simatic-Manager, also with WinCC and Comfort Panel
  • Automatic protocol- and baud rate detection (depends on the used product from 9K6 to 12M)
  • Connects only to the bus when it is requested by PG
  • Firmwareupdate via internet for free
  • PPI - adapter for S7 - 200
  • MPI/Profibus - adapter for S7 - 300 + 400
  • CE/EMC compliant construction
  • All intelligent MPI-interface-products including a free OPC-server license "OPC-Manager lite" [limited to 100 items]
  • All products, including the examples and demo-version of communication driver as download on the product-site
  • Master-class 2 for acyclic services (DPV1)
  • PUT/GET from S7-1500/1200/300/400(PN or with ethernet-cp) with spezific and unspezific connection possible
  • Cyclic read of time from NTP server and set in the connected PLC
  • Coupling with DB-transfer to S7-LAN, S7-Gateway, S7-CP, S5-LAN++ or S5 Gateway
  • Power supply from the S7-PLC or external
  • Network configuration free adjustable
  • VPN remote maintenance possible / for the maintenance of the PLC via Internet
  • Integrated display for output of diagnostic informations
  • Double-sided connected cable
  • Short plug to PLC
  • Provides the coupling with Android operating-system [for example S7Droid]

docu / downloads
applications

Technical data


Supply voltage: 24V/DC +/- 20%
Power consumption: 2,5 watt
Display: double lined LCD-display
Handling/Configuration: Kabelmanager-Software
keypad on the back
Interfaces:
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
to the PD/PC:
10/100MBit ethernet interface
Galvanic separation: 1500V PPI/MPI/Profibus to the PC
Operating temperature: 5 - 55°C
Case: ABS-plastic case
Dimensions: 146 x 41 x 29 mm
Scope of delivery:
MPI-LAN-cable
Power connector 2pins small
Commercial data:
EAN number: 4260363240949
HS-code: 85444290
Weight: 0.3000 kg

technical data
docu / downloads

Applications

Programming of S7-PLCs via LAN

You would like to respond to your S7-PLC-device via LAN but not integrate an Ethernet-CP? No problem, plug the S7-LAN or also the MPI-LAN-cable on the MPI/PPI/Profibus-interface and access via LAN.
Watching of S7-PLC-devices via LAN without Ethernet-CP

Your panel only has a LAN-socket as PLC-interface? No problem, connect this socket with the S7-LAN or the MPI-LAN-cable and plug it directly on the PPI/MPI/Profibus of the PLC. Then access to the variables and data of the PLC is already available.
S7-CP-replacement (without LAN-CP to the PLC-device)

Do you have a S7-PLC-device without CP243-1, CP343-1 or CP443-1 and would like to connect via LAN? Then plug the S7-LAN on the PLC-device and your access via RFC1006 is ready for use.
Remote maintenance / telecontrol of PLC-devices via LAN / internet

You have access to a on-site network and your PLC-device has no LAN-connection? No problem, plug the S7-LAN on the PLC-device and you will have immediate access to the PLC from afar.
Without LAN-cable round of the PLC

Your’re right in the middle of your production line and and should move around the machine and simultaneously observe / manage. No problem, you parameterize the S7-WLAN-Bridge, connect to the MPI-LAN and connect to an access-point or with the ad-hoc-network of your laptop and are ONLINE on the PLC.

Transformation of Rack/Slot in TSAP to MPI-address

Your panel or visualisationsystem addresses the used PLC with Rack/Slot in TSAP? No problem, activate this mode in the MPI-LAN-cable and you will get actual data from the PLC.
PLC-coupling (data exchange between PLC-devices)

Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Thereto no dedicated line is required, it’s sufficient when the stations connect via network (DSL-router).
Actual time for the PLC?

You need in your PLC a actual time? No problem, with the NTP-function the MPI-LAN-cable get from a NTP-(Time-)Server the actual time and transfers it direct into the configured PLC or for processing in a DB.
Variable-chart without Step7-programming package

You would like to give your customer the opportunity to read current numbers of the manufacturing Online, without installing a visualisation or even the STEP7-package? Then a S7-LAN with the option „Status Variable“ is needed, and your customer can take a look at these password protected data on a site of the integrated webserver.
Malfunctions on the Bus although everything is (apparently) connected properly?

The S7-LAN can also be used for controlling/checking the MPI/Profibus. It will be plugged on the Bus so that you can take a look at the status of the busses via software on PC, for example the numbers of parity errors.
applications technical data

technical data
applications
docu / downloads

article:
Art. ID.name
9352-LAN MPI-LAN-cable 3m
PPI/MPI/Profibus up to 12Mbit/s

applications technical data
options:
Art. ID.name
9352-VAST Option "Variable Control"
view of variables in web browser with
setpoint monitoring and e-mail-alerts
9352-WATCHDOG Option Watchdog
controlling of the connected MPI-/Profibus
with webbrowser or over port

applications technical data
accessories:
Art. ID.name
9350-9-CHP CheapConn Busconnector
for PROFIBUS
9350-9-CHP-CC Option CheapConn for MPI
9350-9-CHP+9350-9-CHP-K already mounted
9350-9-CHP-K Connecting cable MPIx to CheapConn
9-pins 1 : 1 plated-through with shield
9350-WAND Wall-mounting
for MPI/PPI + MPI-II + MPI-USB
9352-104 MPI-PC104-card 1 channel up to 12Mbaud   Obsolete
equates to PC104-standard (90.2 x 95.9mm)
9352-104-2 MPI-PC104-card 2 channel up to 12Mbaud   Obsolete
equates to PC104-standard (90.2 x 95.9mm)
9352-24 Power connector 2pins small
cable coupling by screw-connector (small)
9352-RS485-SK Stub-compensator without galv. separation
9361-7 T-Connector to PPI / MPI-Bus
doubling of PPI/MPI/Profibus-port
without bus connector
9391-HH DIN-rail-holder for MPI/PPI
quick and easy assembling on the cap rail
9391-USB USB-powercable for 24V DC, max. 3W
USB-plug type A to 2 open braids
24V DC, maximum current: 125mA (for PC
100mA)
length: 5m
9391.1 24V DC power-supply unit 625mA
Primary 110V - 240 VAC Euro+USA-plug