TPA

TELE-PROFessional-II (TP-II)


Programming of S5- and S7-PLC’s via telephone from afar

  • Secured modem-protocol, no additional software needed
  • UMTS- / VPN- / internet-service
  • Also for PLC’s with ProfiNet
  • SMS and fax sending directly from S7-300/400 (no PLC-programming necessary)
  • Analogue modem couples automatically via ISDN
  • With integrated CP-343-1 / 443-1 functionality
  • Ethernet also for router function
  • PCMCIA-slots (only for version -H) for extensions (memory cards / specific modem cards (GSM) / WLAN)
  • Compatible to the forerunner model (TELE-Prof / TELE-Book / TELE-Link)
  • Also as TCP/IP-router

  • more...

  • Secured modem-protocol, no additional software needed
  • UMTS- / VPN- / internet-service
  • Also for PLC’s with ProfiNet
  • SMS and fax sending directly from S7-300/400 (no PLC-programming necessary)
  • Analogue modem couples automatically via ISDN
  • With integrated CP-343-1 / 443-1 functionality
  • Ethernet also for router function
  • PCMCIA-slots (only for version -H) for extensions (memory cards / specific modem cards (GSM) / WLAN)
  • Compatible to the forerunner model (TELE-Prof / TELE-Book / TELE-Link)
  • Also as TCP/IP-router
  • S7-variables display via Web-Browser
  • S7-remote maintenance with MPI-Interface
  • S5-remote maintenance (access to every S5 direct / via H1, L1, L2 and KOR/MUX)
  • Integrated telephone directory
  • Call-back of partner possible
  • Software-update via PC (LAN) respectively from device to device possible
Remote maintenance / telecontrol of PLC
Produkbild
Access to the connected PLC takes place by coupling via Analogue-, ISDN-, mixed Analogue-ISDN-, GSM-, UMTS-line and also via Internet with and without VPN-security.
Analogue and ISDN - how do they come together?
Produkbild

You have on the plant side only ISDN for telephone, but in your office there is only an analogue system? No problem, you have to install on the clients side the TP-II and activate there the analogue-emulation in the device. No, the modem signals will be send digitalized over ISDN and you can connect to it. So, you will be able to communicate though the telephone systems are different and your client isn´t forced to install an analogue connection.

Router - Mode (access to the network without router)
Produkbild
The Tele-Prof-II can also be used as a router for access from a PC via dial-up connection, so that a communication with the behind covered network results. Furthermore a network connection can be made with the TP-II <=> TP-II-line, but in doing so the IP-address-root must differ.
User dependant network access
Produkbild
You have PLC/LAN-participants different supplier in your network and everybody should have access to this network? No problem, you give every supplier a VPN-username and passwort, define in the destination device a user-dependent network-access and after positiv login he only can communicate to the released ip-addresses.
Separate your machine-net from the office-net
Produkbild
You need a separation between the machine-net and the office-net? No problem, plug a PCMCIA-LAN-card in your Tele-Prof-II-device (only for version -H) and the separation is OK. You have access to both nets via remote maintenance.
S7-CP-alternate (without LAN-CP to the PLC)
Produkbild
Do you have a PLC without CP343-1 or CP443-1 and a TP-II as remote maintenance device? Then activate the CP-mode of the TP-II and your visualisation goes directly ONLINE via the LAN of the TP-II.
PLC coupling (data exchange between PLCs)
Produkbild
Your pumping stations report the water levels of the central control via telephone network. The central office itself can of course transmit commands/messages to the substations as well. Thereto no dedicated line is required, a “normal” telephone connection is sufficient because the devices cut the line after occured message.
Failure report transmission without any change in the PLC programm
Produkbild
Your outstation reports the current value cyclically, or in case of malfunction the status via FAX, as SMS to your mobile phone, to your pager or also via e-mail. And this without an intervention of the PLC-program. Here the variables and actions are stored and processed in the TP-II.
Failure report transmission released by the PLC
Produkbild
Your outstation reports the current value cyclically, or in case of malfunction the status via FAX, as SMS to your mobile phone, to your pager or also via e-mail.
Remote maintenance of centralized PLC-devices
Produkbild
You have many PLC and you want to programm them central on one place? No problem, you have to connect them all to the KOR/MUX-Tele-Switch, connect it with the TP-II and after telephone connect you will be able with the PD-bus-selection of your Step5-software to go ONLINE. Of course the MOR/MUX-Tele-Switch is cascadable, so you can connect up to 30 PLCs to the devices.
Sending ASCII-data to a PC
Produkbild
Your car park or control sends the configuration / capacity utilisation to a PC with a modem, so that the data can be used for further processing.
Direct-mode "extended serial interface"
Produkbild
There is an unsupported control or data logger or converter integrated in your installation which protocol is not supported? No problem, the signs that the PC in the office sends will be transferred via telephone line by the Direct-mode, and on-site reproduced by the TP-II. The way back is identical. So in that case there’s also a communication to the electronic devices available.
Data logger with FTP-interface
Produkbild
You need a data logger which tape-records the specified data of the PLC and you can collect the data via FTP on demand. No problem, TP-II with the option Datalogger is the solution for you.
Supply voltage: 24V DC +/- 20%
Power consumption: 15 watt
Display: expressive LCD display
5 status LEDs
Handling/Configuration: integrated keypad
WEB-Browser
Interfaces:
to the PLC:
PPI/MPI/Profibus interface: 9,6 KBd - 12 MBd
TTY/20mA current loop (AG-TELE aktiv, PLC passiv)
RS232: 9,6 KBd - 115,2 KBd / fully assigned
to the PD/PC:
10/100BaseTX RJ45-ethernet jack
TTY/20mA current loop (100 % mechanically and electr. compatible)
RS232: 9,6 KBd - 115,2 KBd / with a 1on1-cable to the PC
others:
2xUSB, 2xPCMCIA (only for version -H)
Integrated modem: 33K6 HIGH-SPEED, V.42/BIS MNP5 analogue modem
ISDN (Euro ISDN + 1TR6)
Operating temperature: 0 - 55°C
Case: powder coated metal case with mounting flange and DIN-rail mounting
Dimensions: Flat 300 x 175 x 70 mm
Hoch 67 x 280 x 170 mm
Scope of delivery:
Tele-Prof-II
Power connector 3pins big

accessories:

9352.1
USB-cable plug/plug type A-A 3m

USB 1.1 / 2.0 up to 480 MBit
INFOMAIL
by e-mail
9359.1:1
1:1 cable 9pins D-SUB

D-SUB 9pins (male) <=> D-Sub 9pins (female), 1to1-assignment
INFOMAIL
by e-mail
9361-3
S5-connecting cable 3m

forTELE-PROF, MINI-/PG-MUX-II
INFOMAIL
by e-mail
9361-3.05M
S5-connecting cable 5m

for TELE-PROF, MINI-/PG-MUX-II
INFOMAIL
by e-mail
9361-3.06M
S5-connecting cable 6m

for TELE-PROF, MINI-/PG-MUX-II
INFOMAIL
by e-mail
9361-3.10M
S5-connecting cable 10m

for TELE-PROF, MINI-/PG-MUX-II
INFOMAIL
by e-mail
9370-8-AT
Special phone-cable for Austria

RJ12 plug <=> telephone plug of Austria
INFOMAIL
by e-mail
9370-8-BE
Special phone-cable for Belgium

RJ12 plug <=> telephone plug of Belgium
INFOMAIL
by e-mail
9370-8-CH
Special phone-cable for Switzerland

RJ12 plug <=> telephone plug of Switzerland
INFOMAIL
by e-mail
9370-8-D/USA
Phone-cable analogue Germany+USA

RJ12 plug <=> RJ12 plug with TAE-adapter for Germany
INFOMAIL
by e-mail
9370-8-DK
Special phone-cable for Denmark

RJ12 plug <=> telephone plug of Denmark
INFOMAIL
by e-mail
9370-8-FR
Special phone-cable for France

RJ12 plug <=> telephone plug of France
INFOMAIL
by e-mail
9370-8-GB
Special phone-cable for Great Britain

RJ12 plug <=> telephone plug of Great Britain
INFOMAIL
by e-mail
9370-8-ISDN
Phone-cable ISDN

RJ45 plug <=> RJ45 plug, assigned 1to1
INFOMAIL
by e-mail
9370-8-IT
Special phone-cable for Italy

INFOMAIL
by e-mail
9370-8-NL
Special phone-cable for Netherlands

RJ12 plug <=> telephone plug of the Netherlands
INFOMAIL
by e-mail
9370-TAE
TAE junction box

analogue telephone box (NFN) for on-wall mounting
INFOMAIL
by e-mail
9371-6
Servicebag Obsolete

for TP, TB + TP-II-FLAT
INFOMAIL
by e-mail
9372
TELE-PROFessional II Starter-Kit

completing 9372-OEM
INFOMAIL
by e-mail
9372-24
Power connector 3pins big

connector plug lockable by jack with screws
INFOMAIL
by e-mail
9372-LANCARD
Network-card for TP-II Obsolete

Ethernet networkcard Cardbus PCMCIA 10/100
INFOMAIL
by e-mail
9372-UMTS-Ant
UMTS directional antenna
external antenna for the UMTS-card
INFOMAIL
by e-mail
9379.1
MPI-/Profibus connecting cable 1m

connects MPI-modem/TP-II with the S7-PLC
INFOMAIL
by e-mail
9391-MT
Mounting set

for DIN-rail-holder
INFOMAIL
by e-mail
9391.1
24V DC power-supply unit 625mA

Primary 110V - 240 VAC Euro+USA-plug
INFOMAIL
by e-mail
9636-CROSS
Cross-cable 3m Cat5+, shielded

RJ45 plug <=> RJ45 plug, twisted pinning
INFOMAIL
by e-mail
9636-TCPIP
Patch-cable 3m, Cat5+, shielded

RJ45 plug <=> RJ45 plug, 1:1
INFOMAIL
by e-mail

Variationen:

9372-OEM
TELE-PROFessional II worldwide use

OEM - Version (all accessories optional) without PCMCIA-Slot for UMTS-/LAN-card
INFOMAIL
by e-mail

9372-FLAT
TELE-PROFessional II worldwide use

flat version / OEM - Version (all accessories optional) without PCMCIA-slot for UMTS-/LAN-card
INFOMAIL
by e-mail
9372-FLAT-H
TELE-PROFessional II worldwide use
flat version / OEM - Version (all accessories optional) with PCMCIA-slot for UMTS-/LAN-Card
INFOMAIL
by e-mail
9372-OEM-H
TELE-PROFessional II worldwide use
OEM - Version (all accessories optional) with PCMCIA-slot for UMTS-/LAN-Card
INFOMAIL
by e-mail

Automatic-mode

Other downloads

Extension

Support-videos