Cookies helfen uns bei der Bereitstellung unserer Dienste. Durch die Nutzung unserer Dienste erklären Sie sich damit einverstanden, dass wir Cookies setzen.
Cookies help us in providing our services. By using our services, you agree that we set cookies.
OK
TPA

EtherSens Messenger


PLC controlled alarm-message dispatch

  • Sends alarm-messages controlled by the PLC
  • Receiver in the PLC deposited, so ONLINE replaceable
  • Messages in the PLC deposited, so ONLINE replaceable

  • Sends alarm-messages controlled by the PLC
  • Receiver in the PLC deposited, so ONLINE replaceable
  • Messages in the PLC deposited, so ONLINE replaceable
Data backup S5-PLC on FTP-Server
Produkbild

S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on FTP-server

Data backup S5-PLC on FTP-server via dig. IO
Produkbild

Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to FTP-server

Data backup S5-PLC on SD-card
Produkbild

S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on SD-card

Data backup S5-PLC on SD-card via dig. IO
Produkbild

Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to SD-card

Data backup S5-PLC on USB-stick
Produkbild

S5-PLC triggered DB-backup/-restore without additional PC via PG-socket and Ethernet on USB-stick

Data backup S5-PLC on USB-stick via dig. IO
Produkbild

Via digital input triggered DB-backup/-restore without additional PC via PG-socket and Ethernet to USB-stick

Data backup S7-PLC PN-port on FTP-server
Produkbild

S7-PLC triggered DB-backup/-restore without additional PC via PN-port on FTP-server

Data backup S7-PLC PN-port on FTP-server via dig. IO
Produkbild

Via digital input triggered DB-backup/-restore without additional PC via PN-port to FTP-server

Data backup S7-PLC PN-port on SD-card
Produkbild

S7-PLC triggered DB-backup/-restore without additional PC via PN-port on SD card

Data backup S7-PLC PN-port on SD-card via dig. IO
Produkbild

Via digital input triggered DB-backup/-restore without additional PC via PN-port to SD-card

Data backup S7-PLC PN-port on USB-stick
Produkbild

S7-PLC triggered DB-backup/-restore without additional PC via PN-port to USB-stick

DB-Backup/Restore S7-PLC PN-port on USB-stick via dig. IO
Produkbild

Via digital input triggered DB-backup/-restore without additional PC via PN-port to USB-stick

Data backup S7-PLC over MPI/Profibus on FTP-server
Produkbild

S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on FTP-server

Data backup S7-PLC over MPI/Profibus on FTP-server via dig. IO
Produkbild

Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to FTP-server

Data backup S7-PLC over MPI/Profibus on SD-card
Produkbild

S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on SD-card

Data backup S7-PLC over MPI/Profibus on SD-card via dig. IO
Produkbild

Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to SD-card

Data backup S7-PLC over MPI/Profibus on USB-stick
Produkbild

S7-PLC triggered DB-backup/-restore without additional PC via MPI/Profibus on USB-stick

Data backup S7-PLC over MPI/Profibus on USB-stick via dig. IO
Produkbild

Via digital input triggered DB-backup/-restore without additional PC via MPI/Profibus to USB-stick

Message dispatch from the PLC
Produkbild

Send directly from your PLC news, statuses, alarms as SMS or email.

Supply voltage: 24V DC +/- 20%
Power consumption: 2 watt
Display: WEB-Browser
1 status LED bicolor
Handling/Configuration: WEB-Browser
Interfaces: Slot for microSD
Antenna-connector SMA(f) (2.4 GHz IEEE 802.11b/g)
10/100BaseTX RJ45-ethernet-plug
Button for factory settings
Overvoltage category: CAT IV
Insulation value
network <=> mains voltage:
1,5 KV
Operating temperature: 0 - 55°C
Case: ABS-plastic case V0
Dimensions: 100 x 112 x 45 mm
Scope of delivery:
  EtherSens Basic
WIFI-stub-antenna

extensions:

9220-GYRO-SENS-312
Gyro-Sensor 312 für EtherSens
Measuring range: ±1.5g / ±3g / ±6g / ±12g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
INFOMAIL
by e-mail
9220-GYRO-SENS-313
Gyro-Sensor 313 für EtherSens
Measuring range: ±0.5g / ±1g / ±2g / ±4g 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
INFOMAIL
by e-mail
9220-SEG-ANZEIGE
Segment-display for EtherSens
4 Digit 14 segment-display RED 0,56" high in wall-mounting case 5V DC supply (from I2C-interfaceport) I2C-connection
INFOMAIL
by e-mail
9220-SONNE
Sun-light-sensor for EtherSens

max. 220k Lux (switchable ranges) 3.3V DC supply (from I2C-interfaceport) I2C-connection 1m
INFOMAIL
by e-mail
9220-U-I-BOX
U-I-box for EtherSens

max. 1000V DC / 40A 24V DC supply 20cm power-cable 4mm2 with Amphenol-plug I2C-connection 1m
INFOMAIL
by e-mail
9230-AIO
Extension Analog-IO V1.0

Extension-board for EtherSens-devices 4 x analog IN 0-5V opt. with ext.Shunt 0/4-20mA opt. with ext. restistance 0-10/24/50V 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
INFOMAIL
by e-mail
9230-AIO-V1.1
Extension Analog-IO V1.1

Extension-board for EtherSens-devices 4 x Analogue Input (switchable between U, I, differential) 4 x analog OUT 0/4-20mA (24V) Power consumption: 4W
INFOMAIL
by e-mail
9230-DIO
Extension Digital-IO

Extension-board for EtherSens-devices 12 x digital IN or OUT 24VDC 400mA free config with software Power consumption: 4W
INFOMAIL
by e-mail
9230-EI2C-3.3V
Extension with ext. galv. separated I2C 3.3V

Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 3.3V Power consumption: 2W
INFOMAIL
by e-mail
9230-EI2C-5V
Extension with ext. galv. separated I2C 5V

Extension-board for EtherSens-devices with galvanic separated external I2C-connector for 5V Power consumption: 2W
INFOMAIL
by e-mail
9230-ENERGY
Extension Energy-IO

Extension-board for EtherSens-devices Energy-analysis (EN 50470-1 EN 50470-3) L1, L2, L3, N realtime analysis Up to 8000 measurements / second Hz / cos phi / power-factor Energy consumption kWh For Rogwski-coils up to 0,5V
INFOMAIL
by e-mail
9230-GG
Bigger Case
Width 90mm instead of 45mm
INFOMAIL
by e-mail
9230-LTE
Extension LTE-modem

LTE-modem-board for EtherSens-devices Send/receive of SMS-messages Communication from/into internet Power consumption: 6,5W
INFOMAIL
by e-mail
9230-MIO-232
Extension RS232-IO

Extensionboard for EtherSens-devices V1.0 for RS232 (RxD, TxD) Power consumption: 2W
INFOMAIL
by e-mail
9230-MIO-422
Extension RS422-IO

Extensionboard for EtherSens-devices V1.0 for RS422 (4-wire) Power consumption: 2W
INFOMAIL
by e-mail
9230-MIO-485
Extension RS485-IO

Extensionboard for EtherSens-devices V1.0 for RS485 Power consumption: 2W
INFOMAIL
by e-mail
9230-MIO-TTY
Extension TTY-IO

Extensionboard for EtherSens-devices V1.0 for TTY (incl. 2x current-sources) Power consumption: 2W
INFOMAIL
by e-mail
9230-NT-230V
Power-supply-rack-unit 230V

Input voltage: 100 - 240VAC 50-60Hz Output voltage: 24V DC Power: 4W
INFOMAIL
by e-mail
9230-RIO-230V
Extension 230V Relay-IO

Extension-board for EtherSens-devices Supply voltage: 230V AC 4 x relay-OUT 230VAC/16A Power consumption: 2,5W
INFOMAIL
by e-mail
9230-RIO-24V
Extension 24V Relay-IO

Extension-board for EtherSens-devices Supply voltage: 24V DC 4 x relay-OUT 230VAC/16A Power consumption: 4W
INFOMAIL
by e-mail
9230-USB
Extension USB-port

USB-port for EtherSens-devices (data storage) Extension for: - DB-backup/restoure-function - CSV-recording Maximum current: 200mA for 5V DC
INFOMAIL
by e-mail

accessories:

9230-SD-32
Micro-SD-card 32GB

for EtherSens-devices SDHC class 10
INFOMAIL
by e-mail
9352-WLAN-ANT
Magnetic base antenna

for S7-WLAN-Bridge, WLAN-Klemme, EtherSens cable length: 3m
INFOMAIL
by e-mail
9391.1
24V DC power-supply unit 625mA

Primary 110V - 240 VAC Euro+USA-plug
INFOMAIL
by e-mail
9636-CROSS
Cross-cable 3m Cat5+, shielded

RJ45 plug <=> RJ45 plug, twisted pinning
INFOMAIL
by e-mail
9636-TCPIP
Patch-cable 3m, Cat5+, shielded

RJ45 plug <=> RJ45 plug, 1:1
INFOMAIL
by e-mail
9636-TCPIP.02M
Patch-cable 0.25m, Cat5e, shielded

RJ45 plug <=> RJ45 plug, 1:1
INFOMAIL
by e-mail
9636-TCPIP.1M
Patch-cable 1m, Cat5e, shielded
RJ45 plug <=> RJ45 plug, 1:1
INFOMAIL
by e-mail

Variationen:

9201
EtherSens Basic

Operating as a client or access-point Configuration via web-server Supply: 24V DC
INFOMAIL
by e-mail

Automatic-mode

Other downloads

Extension

Support-videos